The White Rodgers 1A16 Series is a heavy duty line voltage heating-cooling thermostat designed for controlling fan motors, circulator motors, contactors, motor starters, valves, etc. It features SPDT snap switch action, fixed anticipators for greater room comfort, and a temperature range of 36° to 90°F. Below are the key specifications, installation, operation, and instructions.
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
CAUTION! To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Use copper conductors only.
WARNING! When thermostat is set below 40°F or 5°C, damage to the building and/or contents may result due to freezing. This is possible due to factory calibration tolerances, thermostat location and operating characteristics of the heating equipment.
The proper location of the room thermostat is most important to insure that it will provide a comfortable home temperature. Observe the following general rules when selecting a location:
This Heavy Duty Line Voltage Heating-Cooling Thermostat is designed for controlling fan motors, circulator motors, contactors, motor starters, valves, etc. To provide greater room comfort, the thermostat is equipped with fixed anticipators.
Two dial stops are supplied, which may be used for making a maximum or minimum setting, a limited temperature range or a locked dial setting. (See parts package).
The temperature may be set anywhere between 36° and 90°F or 2° and 32°C by turning knob to the desired temperature on the dial.
Positive off or system selection can be obtained by using a switching sub-base. Optional heating and cooling sub-base S29-21 is available.
| Model Number | Voltage | Full Load (Heat/Cool) | Locked Rotor (Heat/Cool) |
|---|---|---|---|
| 1A10-651 | 120 | 8.0A / 8.0A | 48.0A / 48.0A |
| 240/277 | 4.0A / 8.0A | 24.0A / 24.0A | |
| 1A16-51 | 120 | 16.0A / 16.0A | 96.0A / 48.0A |
| 240/277 | 8.0A / 16.0A | 48.0A / 24.0A |
Disconnect power at main fuse or circuit breaker. Remove old thermostat if present, label wires. Mount the thermostat base to the wall using provided screws. Connect wires according to the wiring diagram. The thermostat may be mounted in any standard 3" x 2" or 4" x 2" electrical outlet box (deep type recommended).
Typical Wiring Diagram for Heating-Cooling System (Manual Changeover)
MANUAL CHANGEOVER COOL (2) HEAT (1) WINTER SUMMER LINE FAN-COIL GREEN LEAD TO SYSTEM GROUND
Typical Wiring Diagram for Fan-Coil System (Automatic Changeover)
Connect to fan-coil unit: Heat to W, Cool to B, Hot to R, Fan connections.
CAUTION! Do not push or damage the knob sensing element during installation. Avoid hitting the knob when seating stops. Once stops are installed, they cannot be removed.
WARNING! When thermostat is set below 40°F or 5°C, damage to the building and/or contents may result due to freezing.
No specific troubleshooting information is available in this manual. Contact a qualified service technician if issues arise.