The White Rodgers 1F80-41 is a 5-Day/2-Day programmable digital thermostat for heat/cool systems. It features simultaneous programming, 12/24-hour clock, °F/°C. Battery powered with 3 AA. Compatible with standard heat/cool, electric, gas/oil, hydronic, single-stage heat pump, millivolt. Below are the key specifications, installation, operation, programming, and troubleshooting instructions.
FAILURE TO READ... INJURY/DAMAGE.
Features: LCD set/time/temp, override, HOLD, 12/24 clock, °F/°C, 45-90°F, 5 terminals single/two-transformer, 5/2 day, simultaneous storage, B/O heat pump/damper, preprogrammed, 4 periods, 3 AA batteries.
Buttons: Up/down, SET TIME, VIEW PRGM, RUN PRGM, HOLD TEMP, FAN, SYSTEM.
Display: Time/temp, day, AM/PM, HEAT/COOL, BATTERY, HOLD.
Disconnect. Label/remove wires.
Figure 3: Heat only 2-wire RH/RC jumper, W heat.
Figure 4: 3-wire Series 10 Jumper at furnace.
Figure 5: Heat only 3-wire RH/RC jumper, W/G.
Figure 6: Cool only 3-wire RH/RC, Y/G.
Figure 7: Heat/cool 4-wire RH/RC, W/Y/G.
Figure 8: Heat/cool 5-wire two-trans Separate RH/RC.
Figure 9: Heat pump COOL active O changeover.
Figure 10: Heat pump HEAT active B changeover.
Service if issues.
CAUTION <50°F no. COOL flashes lockout.
5/2 day, 4 periods. Factory heat 6AM 68F etc.
Set Time: SET TIME adjust hour/min/AMPM.
Enter: VIEW PRGM for periods, adjust time/temp heat/cool.
Run: RUN PRGM.
| Period | Time | Heat | Cool |
|---|---|---|---|
| 1st | 6:00 AM | 68°F | 78°F |
| 2nd | 8:00 AM | 68°F | 78°F |
| 3rd | 5:00 PM | 68°F | 78°F |
| 4th | 10:00 PM | 64°F | 82°F |
| Symptom | Cause | Action |
|---|---|---|
| No Heat/Cool | Fuse. OFF. | Reset. ON. |
| No Heat | Pilot. Wires. | Light. Check. |
| No Cool | Wires. <50°F. | Check. Avoid. |
| Constant | Short. | Inspect. |
| Cycles | Location. | Relocate. |
| Disagree | Calib. | Adjust ±4°. |
| BATTERY | Low. | Replace AA. |