The White Rodgers 1F85ST-0422 is a programmable electronic digital thermostat with Spanish display for single-stage, multi-stage, or heat pump systems with automatic heat/cool changeover option. It features 5+1+1 or 5+2 day programming, installer configuration menu, and energy-saving features like Cool Savings. Battery-powered with 2 AA batteries; compatible with 24V systems up to 1.5A per terminal. Below are the key specifications, installation, operation, programming, and troubleshooting instructions.
Assemble tools: hand or power drill with 3/16 inch drill bit (if needed), flat blade screwdriver, wire cutter/stripper, level. Shut off electricity at main fuse box until installation complete. Label wires before disconnecting. This thermostat is for 24V systems only; not for millivolt or line voltage. Install away from drafts, direct sunlight, or heat sources for accurate sensing. Note: Display shows Spanish text.
WARNING! Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage. Save these instructions.
ATTENTION! This product does not contain mercury but may replace one that does. Do not open mercury cells; if damaged, wear non-absorbent gloves, clean up spilled mercury, place in sealed container. Refer to www.thermostat-recycle.org for disposal.
The thermostat consists of cover and base. Features LCD display showing time/room temperature alternating with set point (in Spanish), up/down arrows for adjustment, SYSTEM switch (COOL/OFF/HEAT/EMER), FAN switch (ON/AUTO), O/B switch for changeover (factory "O" for COOL energized). Terminals: R, C, Y, Y2, G, W/E, W2, O/B, L. Supports heat pump with/without aux/emergency heat, up to 2-stage heat/cool, heat-only/cool-only systems.
Applications: Heat Pump (No Aux/Emergency Heat): Yes; Heat Pump (with Aux/Emergency): Yes; Standard Heat/Cool: No; Heat Only: Yes (optional fan); Millivolt Heat Only: Yes; Cool Only: Yes; Gas/Oil Heat: Yes; Electric Furnace: Yes; Hydronic 2/3 Wires: Yes.
CAUTION! To prevent electrical shock/equipment damage, disconnect power at main fuse/circuit breaker until installation complete. Label wires prior to disconnection.
WARNING! Do not use on circuits exceeding 20-30 VAC 50/60 Hz or DC (0.05-1.5A per terminal, 2.5A max total); higher voltage damages control/causes shock/fire. Do not short terminals on gas valve/primary control to test; short/incorrect wiring burns out components/causes injury/property damage. Conform to NEC Class II circuits.
CAUTION! Below 50°F, do not operate cooling (compressor damage). For electric heat/single-stage heat pump, set GAS/ELEC if fan energizes on heat call. For hydronic, clip W905 for longer cycles.
A standard heat/cool thermostat consists of three basic parts: 1) Cover (snap-on/hinge type); 2) Base (loosen captive screws); 3) Switching subbase (unscrew from wall/adaptor). Label each wire with terminal designation before disconnecting. Disconnect wires one at a time; do not let fall into wall. If wall mounting plate exists, remove thermostat and plate as assembly.
Pull thermostat body off base (do not force/pry). Place base over wall hole, mark mounting holes, drill, fasten with screws (level for appearance). Connect wires to terminals. Push excess wire into wall, seal hole with fire-resistant material (e.g., fiberglass). Snap cover on.
Batteries: 2 AA alkaline (replace every 2 years; low shows battery icon/"Change Battery"). Insert positive (+) to right. For unoccupied homes >3 months, replace if icon displayed. Offset occurs when <2 months life remains (±10°F); reset manually.
Terminal Designations: L (malfunction indicator), O (changeover COOL), B (changeover HEAT), Y (compressor), Y2 (2nd stage compressor), W/E (heat/emergency relay stage 1), W2 (2nd stage heat/HP1), G (fan), RH (heating power), RC (cooling power), C (common), 6 (3-wire zone valve).
Single Transformer Systems: R to 24VAC hot, C to neutral, Y to compressor, G to fan, W2 to aux (stage 2), E to emergency, O/B to changeover (energized in COOL if "O"). Jumper for single aux both stages.
Two Transformer (No Safety Circuits): Separate transformers; jumper commons. Polarity observed; cut/tape unused.
Two Transformer (Safety in Both): Accessory relay N.O. for safety; jumper commons.
CAUTION! Refer to equipment manuals for specifics. Tighten securely; keep wires clear.
Touch side to release static before keys. Restore power. If system fails, contact serviceperson.
CAUTION! Do not operate below 50°F.
Factory preprogrammed; RESET (back) to restore. 5+1+1 or 5+2 day; 4 periods/day.
Factory Heat: Wake 6AM 70°F, Leave 8AM 62°F, Return 5PM 70°F, Sleep 10PM 62°F. Cool: Wake 74°F, Leave 80°F, Return 74°F, Sleep 78°F.
SYSTEM to HEAT/COOL/EMER/AUTO; hold MENU 5s. Press MENU to advance; up/down to change.
| Screen # | Display (Default) | Options | Comments |
|---|---|---|---|
| 01 | (OFF) Lk L | - | Keypad Lockout |
| 02 | (000) Lk 001-999 | - | Lockout Code |
| 03 | (MS 2) HP 1, SS 1 | - | Multi-Stage/HP/Single |
| 04 | (GAS) ELE | - | Gas/Electric Heat |
| 05 | (0) CS 1-6 | - | Cool Savings |
| 06 | (On) E OFF | - | EMR (1F85 only) |
| 07 | (ME) CR Heat SL, FA | - | Heat Cycle Rate |
| 08 | (ME) CR Cool SL, FA | - | Cool Cycle Rate |
| 09 | (ME) CR HP SL, FA | - | HP Cycle Rate |
| 10 | (FA) CR Emer SL | - | Emer Cycle Rate |
| 11 | (OFF) CL On | - | Compressor Lockout |
| 12 | Heat-Auto-Cool-Off | Various | System Mode Config |
| 13 | (On) dL OFF | - | Display Light |
| 14 | 0 (current temp) | ±4 | Ambient Adjustment |
| 15 | °F | °C | Temp Display |
| 16 | L (90) Heat 62-89 | - | Heat Limit |
| 17 | L (45) Cool 46-82 | - | Cool Limit |
| 18 | P3 (5+1+1) | P0, P2 | Programming Type |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank Display/No Operation | Low batteries; power loss. | Replace AA batteries; check wiring. |
| Heating/Cooling Not Working | SYSTEM mode wrong; setpoint not met; wiring issue; system fault ("Call For Service"). | Set to HEAT/COOL, adjust setpoint; verify wires; service system. |
| Fan Not Running | FAN mode AUTO but no call; wiring. | Set FAN ON; check G terminal. |
| Short Cycling | Cycle rate too fast; location. | Adjust in config menu (slow); relocate thermostat. |
| Change Filter Reminder | Filter time reached. | Change/clean filter; reset in menu. |
| Compressor Lockout | Cycling too quick. | Wait for auto-reset (5 min). |