The White Rodgers 1F96 Series is a non-programmable digital thermostat from the Comfort-Set III series for single-stage heat/cool, heat pump, or heat only/cool only systems. It features occupied/unoccupied setpoints, automatic changeover, compressor protection, fan on/off delays, and configuration options for various fuel types. Powered by 24 VAC; compatible with systems up to 1.5A per terminal, 1.5A max total. Below are the key specifications, installation, operation, configuration, and troubleshooting instructions.
Assemble tools: hand or power drill with 3/16 inch drill bit (if needed), flat blade screwdriver, wire cutter/stripper, level. Shut off electricity at main fuse box until installation complete. Label wires before disconnecting. This thermostat is for 24V systems only; not for line voltage. Install away from drafts, direct sunlight, or heat sources for accurate sensing.
Remove Old Thermostat: Disconnect power, remove front cover, label wires, disconnect one at a time.
WARNING! Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage. Save these instructions.
The thermostat uses microcomputer technology to provide precise temperature control. Features occupied/unoccupied setpoints, automatic/manual changeover, compressor short cycle protection (5-min), programmable fan delays, backlit display. LCD shows room temp/setpoint, up/down arrows, SYSTEM switch (HEAT/OFF/COOL/AUTO), FAN switch (ON/AUTO). Terminals: R (hot), C (common), G (fan), Y (compressor), W (heat), O/B (changeover).
Applications: Gas/Oil/Electric Heat: Yes; Hot Water/Steam: Yes; Single Stage Heat Pump: Yes; Heat Only: Yes; Cool Only: Yes; Millivolt: Yes; Zone: Yes.
CAUTION! To prevent electrical shock/equipment damage, disconnect power at main fuse/circuit breaker until installation complete. Label wires prior to disconnection. If in doubt about wiring, consult qualified heating/air conditioning contractor.
WARNING! Do not use on circuits exceeding 17-30 VAC 50/60 Hz (0.05-1.5A per terminal, 1.5A max total); higher voltage damages control/causes shock/fire. Do not short terminals on gas valve/primary control to test; short/incorrect wiring burns out components/causes injury/property damage. Conform to NEC Class II circuits. Do not operate cooling below 50°F (compressor damage).
ATTENTION! This product does not contain mercury but may replace one that does. Do not open mercury cells; if damaged, wear non-absorbent gloves, clean up spilled mercury, place in sealed container. Refer to www.white-rodgers.com for disposal. Handle to avoid static discharge.
A standard heat/cool thermostat consists of three basic parts: 1) Cover; 2) Base; 3) Subbase. Label each wire with terminal designation before disconnecting. Disconnect wires one at a time; do not let fall into wall.
Remove old thermostat. Mount new base level on wall, connect wires to terminals. Push excess wire into wall, secure base, attach thermostat body. Power up and configure jumpers/menu.
Terminal Designations: R (24V hot), C (common), Y (compressor), G (fan), W (heat), O/B (changeover).
Standard System: R to hot, C to common, Y to compressor, G to fan, W to heat.
Millivolt System: Connect to millivolt gas valve.
Hydronic System: W to zone valve, R to transformer via valve.
Heat Pump: Y compressor, O/B changeover (O cool, B heat).
CAUTION! Red jumper between RC and RH for single transformer. Refer to equipment manuals for specifics.
Restore power. Set SYSTEM to HEAT/COOL, FAN to ON/AUTO, adjust setpoint to test.
CAUTION! Do not operate below 50°F.
Non-programmable thermostat. Setpoints are manually adjusted for occupied/unoccupied modes. No scheduling features.
Configure jumpers on back before powering on. Enter menu by pressing HOLD + UP for 5 seconds. Use UP/DOWN to adjust, HOLD to advance.
| Option | Factory Default | Options | Comments |
|---|---|---|---|
| System Type | SS1 | SS1/HP1 | Single Stage/Heat Pump |
| Fan Control | GAS | GAS/ELEC | Fossil fuel/Electric |
| Changeover | AUTO | AUTO/MAN | Auto/Manual |
| Cool Fan On Delay | 0 sec | 1-5 sec | Call for cool |
| Cool Fan Off Delay | 0 sec | 1-127 sec | After cool satisfied |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display Blank | Power loss. | Check transformer/wiring; restore power. |
| System Not Responding | Wiring error, configuration. | Verify wiring, jumpers/menu settings. |
| Incorrect Temperature | Setpoint, mode. | Adjust occupied/unoccupied setpoint. |
| Fan Not Running | AUTO no call; wiring. | Set ON; check G terminal. |
| Short Cycling | Protection delay. | Wait 5 min; override for testing. |
| Compressor Won't Start | 5-min lockout. | Wait; check flashing indicators. |